Teca Synergy Patient Interface Unit (PIU)
Synergy PIU
2 Channel EMG/SEP Systems
General Specifications
Consists of a Patient Interface Unit (PIU), external speaker, medical grade power supply, and a computer with Synergy System Software
Patient Interface Unit (PIU)
Size: 156 mm W x 55 mm D x 241 mm H (6.2” x 2.2” x 9.5”) Weight: Approximately 1 kg (2.2 lbs)
External Speaker
Size: 131 mm W x 66 mm D x 62 mm H (5.2” x 2.6” x 2.4”) Weight: 370 g (13 oz)
Medical Grade Power Supply
Size:129mmx77mmx42mm(5.1”x3.1”x1.7”) Weight: 510 g (1 lb 2 oz)
Power Requirements
ISO-1050VA Mains Isolation Transformer
Input 100 V-120 V/200 V-240 V, 50-60 Hz, 1050 VA max
Medical Grade Power Supply
Input: 100-240 V~, 50-60 Hz, 1A max.
Output: 15 Vdc 6A
Note: Fuses are internal (there are no user-accessible fuses)
Display
Notebook
14” TFT-LCD with maximum 1280 x 800 (WXGA) resolution
Tower
19” TFT-LCD display 1440 x 900, maximum 1280 x 1024 (WXGA) resolution
Speaker Unit
Audio Input Approximately 500 mVpk-pk for full output Maximum Power to Internal Speaker Approximately 1.75 Wrms Speaker 50 mm (2”) diameter
Synergy Language Support
Configurable to English (UK), English (US), French, German, Italian and Spanish
CareFusion Middleton WI
carefusion.com
System Architecture
Synergy Tower
Intel Core 2 Duo Processor, 3.1 GHz, 2 GB RAM, 250 GB hard drive minimum
Synergy Notebook
Intel Core 2 Duo Processor, 2.53 GHz, 2 GB RAM, 250 GB hard drive minimum
DVD ±RW
Ethernet Network Card
Printer (optional) Laser
Keyboard language-dependent(English-UKandUSA,French,German,Italian,Spanish) Mouse USB
Microsoft Office Language-dependent (English - UK and USA, French, German, Italian, Spanish)
Network Ready
Synergy Software Language-dependent (English - UK and USA, French, German, Italian, Spanish)
Operating System Software
Microsoft® Windows® XP Professional
Electrical Stimulators
Single electrical stimulator. Switchable constant voltage or constant current with a low or high range.
Repetition Rates 0.06 to 200 pps ±5% fine control
Stimulus Duration 0.02, 0.05, 0.1, 0.2, 0.5, 1.0 ms (0.02 ms ± 10%, 0.05 to 1.0 ms ± 5%) Output Type Constant Current or Constant Voltage
Range High:0-100mA,or0–300V Low:0-25mA,0–75V Delay + 0 to 9 screen divisions
Stimulus Modes Single
Amplifiers and Filters
Optically isolated amplifiers with 2 channels
Input Impedance 1000 MΩ ±10%, < 30 pF
CMRR >110 dB
Noise < 0.7 μV r.m.s (0.1 - 10 kHz bandwidth, inputs short circuited)
Low Frequency (-6 dB/octave) 0.1, 1, 3, 10, 20, 30, 50, 100, 200, 250, 300, 500, 1000 and 2000Hz(±10%) 1,1.5,2,3,5,10,20KHz
High Frequency (-12 dB/Octave) 100, 200, 250, 300, 500, 1000 Hz 1, 2, 3, 5,10K Hz (±10%)
Notch Filter 50 Hz or 60 Hz or OFF, attenuation of 25 dB minimum
Data Acquisition
A-D Conversion 16 Bit ADC
Sweep Duration 1 ms to 50 s per channel (independent control per channel) LongTraceTM Facility Continuous acquisition of up to 200 x sweep duration (1000s) Averager Mode Mean, Rectified
Artifact Rejection Configurable per channel
Display Sensitivity 0.01 μV to 100 mV/div
Other External Connectors
Stimulator A
Amplifier connection Footswitch
Temperature probe input
Standard Software
Full patient database with user-configurable fields (ODBC compliant) Protocol Wizard for user-defined test settings
On-line Report Generation software, Microsoft Office compatible On-line Help
Specifications, design options and terms quoted are subject to change without notice
© 2010 CareFusion Corporation or one of its subsidiaries. All rights reserved. Lit. No. 169-438900 Rev 01 (2010/08)
Latest Testimonial
"The Synergy system is exactly as you. write - everything is in excellent condition! The equipment exceeds my expectations. Really, thank you to your company for the sale and the entire shipping and tax process. You are a great director and manager. And you really care about your customers.
I think I will be happy to buy another equipment from you in about 2-3 years. Of course, I will recommend your company to my friends"
Best regards,
M. Marciniec
Lublin, Poland